|
Four styles of controller are listed as follows. The
push button controller is of modular design concept, and different styles
of push button can mix and
match to clip onto the wall plate.
1) 1-gang push button Group controller
2) 2-gang push button Group controller
3) 4-gang push button Scene controller
4) 1-gang rotary Group controller
|
|
|
|
|
|
|
|
|
|
1-gang push button Group controller sends out commands to one Group only,
like Group 1. The selection
of Group is done by turning the dial at the back of Group controller. The button
operations are listed as follows,
a. Press the upward arrow button momentarily to turn on the light
b. Press and hold the upward arrow button to dim up the light
c. Press the downward arrow button momentarily to turn off the light
d. Press and hold the downward arrow button to dim down the light
|
|
|
|
|
|
|
2-gang push button Group controller sends out commands to two consecutive Groups, like Group 1 and 2. The selection of
Groups is done by turning the dial at the back of Group controller. The button
operations are listed as follows,
a. Press the upward arrow button momentarily to turn on the light
b. Press and hold the upward arrow button to dim up the light
c. Press the downward arrow button momentarily to turn off the light
d. Press and hold the downward arrow button to dim down the light
|
|
|
|
|
|
4-gang push button Scene controller sends out commands to four consecutive Scenes, like
Scene 1, 2, 3 and 4. The selection of Scenes is done by turning the dial at the back of Scene
controller. The button operations are listed as follows,
a. Press Button A is to go to Scene number same as the one set at the dial
b. Press Button B is to go to Scene number of one increment of Button A
c. Press Button C is to go to Scene number of one increment of Button B
d. Press Button D is to go to Scene number of one increment of Button C
|
|
|
|
|
|
1-gang rotary Group controller sends out commands to one Group only. The selection
of Group is done by turning the dial at the back of Group controller. The button
operations are listed as follows,
a. Press the toggling knob momentarily to turn on/off the light
b. Turn the knob clockwise to dim up the light
c. Turn the knob anti-clockwise to dim down the light
|
|
|
|
|
|
|
Duplex receptacle wall outlet of 15 Ampere and 120VAC rating is
installed with a relay-operated controller to switch ON/OFF load,
such as coffee maker, kettle, incandescent luminaires. The
controller receives the DALI command to turn on and off the electrical outlet.
For instance, the user sets a scheduled time of 7:00 am at the
DaliTablet to turn on the kettle before going to bed.
Next morning at 7:00 am precisely, DaliTablet sends out the the DALI
command to the relay-operated controller, which
then turns on the kettle.
|
|